Ontario electrical code kitchen counter receptacles.
The following guide includes the canadian electrical code in effect as of february 1 2019.
Kitchen islands and new receptacle requirements in the 2020 nec.
Understanding the kitchen split receptacle circuit.
Electrical code basics and recommended practices for kitchen renovation often seem like pointless rules cooked up in an office boardroom as electrical code eventually does get hammered out across conference tables.
Kitchen wall not counter receptacles 2015 code separate branch circuit required 2018 code separate branch circuit not required wall receptacles provided in a kitchen are required to be supplied by a separate circuit.
A receptacle outlet is then required for every additional 1 7 m 2 18 ft 2 of countertop or work surface.
A 20 amp receptacle is designed to accept the special plug on heavier use appliances and if such an appliance plugs into a 15 amp circuit there is a danger of drawing too much power and.
Electricians contractors and other industry professionals.
Since it is not desirable to use an extension cord on these devices most electrical codes require a higher number of electrical outlets above a kitchen counter than anywhere else in the home.
In addition at least one receptacle outlet should be located within 600 mm 2 ft of the outer end of.
This guide is meant to assist users and every effort has been made to ensure it reflects the current code however where discrepancies between this and.
When planning out kitchen receptacle placement it is important to remember that the rule talks about counter work surfaces not wall spaces.
Trish what you have is actually a perfectly normal situation which meets the code rules in many electrical jurisdictions.
This is what is known as a split receptacle kitchen circuit.
However this requirement predates the requirement for counter receptacles and circuits.
These kitchen designs mean that electrical contractors need to find new ways to satisfy rule 26 712 d iii which outlines the number of receptacles needed and provides a method to determine location.
Small kitchen appliance cords such as coffee pots toasters and mixers rarely have a power cord that is more than 24 inches long.
There is no danger to installing 15 amp outlet receptacles on a 20 amp circuit in fact this is the standard practice but under no circumstances should a 20 amp receptacle be installed on a 15 amp circuit.
Methods of wiring a home may be used but must meet the canadian electrical code.
There can be no part of the countertop farther than 24 inches from an outlet which means that the maximum spacing between countertop receptacles is 48 inches.